As the UK’s leading Air Cooled Condenser installation, repair and maintenance company TEC have considerable knowledge in the efficient operation of all types, make and size of dry air cooling systems from heat exchangers through to fin fan coolers and industrial air cooled condensers. This technical expertise enables us to determine and recommend areas where significant improvements can be made, these include:

 

Control Logic

 
Efficiency losses

 
Fan settings

 
Environmental conditions

 
Energy efficiency

 
Cleaning routines

 
Thermal Imaging

 
De-aeration

 
Vacuum pressures

Air Cooled Condenser

TEC’s technical studies measure and compare current performance against the original design specification to identify where efficiency losses are occurring and the measures required to restore performance to the original.


Our repair and maintenance service includes all elements necessary to ensure efficiency, reliability and cost effective performance, these include:

 

 

Planned and routine mechanical maintenance

 

Fan speed adjustment, balancing and blade tuning

 

Checking for and sealing air leaks in the bundles

 

Gearbox and motor replacement and refurbishment

 

Specialist internal and external cleaning

 

Wind wall netting and bird mesh

Our clients include all the major power generators and petrochemical companies and all the key manufacturers themselves for whom we erect, install, commission and undertake warranty work throughout the world.

 


Cleaning and Maximising Air Flow


The importance of keeping air cooled condenser bundles clean cannot be understated. To be effective, cleaning equipment should be designed specifically for each condenser and bundle layout to ensure 360˚ cleaning of each tube and full penetration of all tube rows.

 

Water must be sprayed in a focused beam in a 15° triangle, be as narrow as possible and the nozzle pressure should be between 80 and 100 bar so that as the beam is directed onto the areas where fouling has accumulated the dirt is forced and washed out.


TEC’s cleaning heads are designed specifically for each ACC bundle arrangement to ensure thorough and effective cleaning as illustrated below:

 

Fin Fan Tube Bundle Fin Fan Tube Bundle Fin Fan Cleaning

 

As and when cleaning is due, TEC provide a complete cleaning service complete with all the necessary equipment and / or operate existing cleaning systems using our specially designed cleaning heads .The cleaning rig is fully automatic and travels vertically up and down the full length of the bundle whilst moving horizontally along the street at a pre-determined speed.


This provides an effective and economic solution to cleaning and as the pictures above illustrate, cleans thoroughly and results in a significant increase in air flow.
 


Thermal Efficiency


Air Cooled Condensers are affected by a number of factors, they deteriorate over time, are susceptible to adverse weather and in many cases contain design inefficiencies and the negative effect of any one or more of these can dramatically reduce cooling efficiency resulting in lost production. These losses can be enormous as illustrated on the chart below depicting a hot (Jul – Aug 2004) summers day:

Ambient Temperatures

Fact:

 

For every 1° rise in temperature above 30° European Generating Capacity Reduces by 10%

 

Inefficient or old Air Cooled Condensers are affected similarly

Although the above illustrates the effect within the power generation industry the same applies to all processes where dry air coolers are in use, the consequences being;

 

 

Reduced production levels and lost revenue

 

Reduction in output when there is the opportunity to capitalise on rising electricity cost

TEC use comparative data to determine current performance against original design specification and can identify areas for improvement. Our detailed studies encompass a full and thorough analysis of the following;

Fan Cells

Air flow volume m/s, surface area contact and heat transfer effectiveness

 
Condenser coils and fins, obstructions and cleanliness

 
Motor ratings, gear ratio, fan speed, blade size and pitch

 
Environmental factors e.g. wind shielding

 
Energy Consumption

Our technical studies are extremely thorough and as a measure of our confidence we undertake to make no charge should we be unable to identify any improvements delivering tangible financial returns. Recommendations are fully costed and following implementation a further study will confirm the effectiveness of the measures taken, cost savings achieved and value of increased production.

copyright

© Copyright 2005 for Thermal Energy Construction Limited by Webspace Unlimited.

bottom menu

| Home |

| Wet Cooling | Dry Cooling | Construction | Steam Boilers | News | Company Information | Clients | Documents |

Health & Safety | Quality Assurance | Photo Library | Frequently Asked Questions | Site MapContact |

 

Thermal Energy Construction UK – Power Plant Contractors & Cooling Tower Maintenance